Recognition of ventricular fibrillation concomitant with pacing artifacts
1,Teaching Department for Emergency Medical Services Wroclaw Medical University
2,Department of Cardiology Wroclaw Medical University
3Department of Anaesthesiology and Intensive Therapy, Wroclaw Medical University
4,2nd Department of Surgery Wroclaw Medical University
*Corresponding Author(s): ZYŚKO DOROTA E-mail: dzysko@wp.pl
Introduction. In pre-hospital settings recognition of underlying rhythm in patients with ventricular stimulation can be difficult especially when a 3-lead electrocardiogram (ECG) is analyzed. This fact is particularly important in patients with life-threa-tening cardiac dysrhythmias. The pacing spikes in the ECG of a patient with cardiac arrest due to ventricular fibrillation may be misdiagnosed as QRS complexes.
Aim of the study. The aim of this study was to assess emergency medical care students’ accuracy in recognizing ventricular fibrillation when pacing spikes are present.
Material and methods. The study group consisted of 39 emergency medical care students, 16 males and 23 females, aged 21 - 23. Subjects were at the midpoint of their 3-year university healthcare professional education. Subjects were asked to interpret electrocardiograms presenting ventricular fibrillation with concomitant pacing artifacts, ventricular fibrillation and atrial fibrillation with ventricular pacing, respectively. Students were trained in recognition of ECG tracings presenting ven-tricular stimulation, atrial fibrillation and ventricular fibrillation. They were instructed that the duration of the QRS complex in adults is at least 0.06s and that pacemaker stimuli are shorter. Prior to the examination, an electrocardiogram similar to the abovementioned, with ventricular fibrillation and pacemaker stimuli, was not presented.
Results. Only one student (out of 39) recognized ventricular fibrillation with pacemaker stimuli present; the majority of stu-dents (92%) incorrectly interpreted the rhythm as atrial fibrillation or atrial flutter. The ECG with isolated ventricular fibrillation was correctly interpreted by all but two students who recognized polymorphic ventricular tachycardia and 62% of students correctly recognized ventricular pacing whereas none of them recognized atrial fibrillation.
Conclusions. 1. The skills of recognizing ventricular fibrillation in patients with concomitant ventricular pacing are poor among emergency medical care students.
2. The ECG tracing showing concomitant ventricular fibrillation and pacing stimuli should be included in teaching programs for emergency medical care students. An ongoing quality improvement program may reduce the rate of mistakes in ECG analysis in rare cases with life-threatening emergencies.
ventricular fibrillation, cardiopulmonary resuscitation, trai-ning, cardiac pacing
SMEREKA JACEK,ZYŚKO DOROTA,CHĘCIŃSKI IGOR,GAJEK JACEK,GOŹDZIK WALDEMAR,WRÓBLEWSKI PAWEŁ,TERPIŁOWSKI ŁUKASZ ,ANIL KUMAR AGRAWAL. Recognition of ventricular fibrillation concomitant with pacing artifacts. Signa Vitae. 2013. 8(1);36-39.
1. Mond HG, Whitlock RM. The Australian and New Zealand cardiac pacing and implantable cardioverter-defibrillator survey: calendar year 2005. Heart Lung Circ 2008;17:85-9.
2. Bonvini RF, Camenzind E. Pacemaker spikes misleading the diagnosis of ventricular fibrillation. Resuscitation 2005;66:241-3.
3. Deakin CD, Nolan JP. European Resuscitation Council Guidelines for Resuscitation 2005. Section 3. Electrical therapies: Automated external defibrillators, defibrillation, cardioversion and pacing. Resuscitation 2005;67S1:S25-37.
4. Yamamoto T, Takayama M, Sato N, Yodogawa K, Iwasaki YK, Kato K, et al. Inappropriate analyses of automated external defibrillators used during in-hospital ventricular fibrillation. Circ J 2008;72:679-81.
5. Monsieurs KG, Conraads VMA, Goethals MPN, Snoeck JP, Bossaert LL. Semi-automatic external defibrillation and implanted cardiac pacemakers: Understanding the interactions during resuscitation. Resuscitation 1995;30:127-31.
6. Natale A, Sra J, Axtell K, Akhtar M, Newby K, Kent V, et al. Undetected ventricular fibrillation in transvenous implantable cardioverter-defibrillators. Prospective comparison of different lead system-device combinations. Circulation 1996;93:91-8.
7. Peberdy MA, Kaye W, Ornato JP, Larkin GL, Nadkarni V, Mancini ME, et al. Cardiopulmonary resuscitation of adults in the hospital: a report of 14720 cardiac arrests from the National Registry of Cardiopulmonary Resuscitation. Resuscitation 2003;58:297-308.
8. Menz V, Schwartzman D, Drachman D, Michele JJ, Dillon SM. Recording of pacing stimulus artifacts by endovascular defibrillation lead systems: comparison of true and integrated bipolar circuits. J Interv Card Electrophysiol 1998;2:269-72.
Science Citation Index Expanded (SCIE) (On Hold)
Chemical Abstracts Service Source Index
Scopus: CiteScore 1.3 (2024)
Embase
Top